IC600CB504

GE Fanuc | Series Six | In Stock Ships Today GE Fanuc Series Six IC600

IC600CB504 Image

IC600CB504

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: Internal Memory Control Mdl (for use in Model 600 or 6000)
  • Weight: 3 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC600CB504 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

INTERNAL MEMORY MODULE GENERAL DESCRIPTION The Internal Memory module is utilized in the Series Six Model 600 and 6000 Central Processor Units (CPU ) to provide Complimentary Metal-Oxide Semiconductor (CMOS), battery-backed, storage of I/O and Series Six Programmable Controller (PC) status data. The features and benefits of this module are summarized in Table 1. The module contains Table and Scratchpad memory. The Table memory is categorized into three groups: Status Table, Override Table and Transition Table. The Scratchpad memory contains miscellaneous information pertaining to the Series Six PC and the user program. The contents of the Internal Memory module, as described above, are accessible to the user at the Program Development Terminal (PDT). This module also provides an array of Dual In-Line Package (DIP) switches by which the user can indicate to the CPU the size of the total user memory space (called Logic Memory), in 2K increments. Two Light-Emitting Diodes (LEDs) are visible through a lens on the module faceplate. An LED marked, BATTERY , indicates the charge of the on-board Lithium battery; another, marked, PARITY , indicates a parity error resulting from a Logic Memory access. The LEDs operate only when the module is installed in a properly powered CPU rack. Refer to Figure 1 for Internal Memory module specifications. TABLE 1. FEATURES AND BENEFITS I FEATURES 1 BENEFITS Battery back-up of CMOS Memory. Protects Table and Scratch Pad data after power-down or power failure. c L I I Parity-error indicator. I Simplifies troubleshooting. I I Battery-Status indicator. I Warns user of need for battery replacement. I ?? Dimensions: Circuit Board: 8.15 x 11.0 (inches) 208 x 280 (mm) Faceplate: 12.45 x 1.175 (inches) 317x 30 (mm) ?? Power Requirements: 5 Vdc, 650 mA maximum (Supplied by CPU power supply) ?? Storage Temperature: 0o co 70oC ?? Operating Temperature: O to 60 C - Humidity: So/o-95% (non-condensing) FIGURE 1. SPECIFICATIONS 89. u.S.A. ASO. NB. 448297015-G01 TMCP1 FAB.NO. 445296382 001 /5 INTERNAL MEMORY BATTERY PARITY O Programming Switches for Logic Memory: Sixteen, 2K-increment switches for each logic memory slot: A, B, C, and D. To set switches, consult the Installation setion of this sheet and/or the Series Six Installation and Maintenance Manual (GEK-25361). 0 Lithium-Manganese Dioxide (Li/Mn02) Battery O Battery Connectors BATTERY Light Steady On: Battery Normal Flashing: Battery Low: CPU continues running. No. 2 alarm is activated. To protect the memory contents, replace the battery before it fails. Steady Off: Battery Failed: CPU continues running, but does not restart of stopped. No. 2 alarm remains activated. Memory contents are lost when power is switched-off, or lost. For battery replacement information, consult the Series Six Installation and Maintenance Manual. PARITY Light: ON: Logic memory parity is OK. Off: Logic Memory parity error exists. An error message appears in the work area of the Program Development Terminal display. FIGURE 2. USER ITEMS 2 Ref. PC-S6-84-0151 Internal Memory Module GEK-83501 INSTALLATION The Internal Memory module can be installed in the Model 600 and Model 6000 CPU. However, before inserting the module into the CPU rack, the array of Dual- In-Line-Package (DIP) switches (Refer to Figure 3) must be set to indicate to the Series Six CPU the amount and position of the Logic Memory (user memory) resident in the rack. A, then B, then C, and finally D. (32K of Logic Memory, or sixteen, 2K increments, is the maximum amount of Logic Memory in a Model 6000 CPU rack.) Further discussion of the DIP-switch array programming can be found in the Installation section of the installation and Maintenance Manual, GEK-25361. Having set the DIP-switch array, follow these steps: 1. Do not change the settings of the programming switches on this module with a program loaded into the logic memory system. Failure to observe this WARNING will cause the user program to be run out of sequence and could result in damage to plant equipment and/or injury to personnel. The columns, D, C, B and A correspond to the Logic Memory module slots in the Model 6000 CPU as indicated in Figure 4. (The Model 600 CPU utilizes slot A , only). The 2K increments are selectable by individual rocker switches as indicated on the right side of the DIP-switch array. No more than 8K of memory (four, 2K increments) can be assigned to a Logic Memory slot (D, C, B or A); the user is advised to assign a consecutive addressing scheme (as shown in Figure 3) starting with slot 32K Remove top board cover after pinching white, plastic fasteners. Connect 2-pin Lithium battery connector to either of male jacks beneath battery. Place top board cover over component side of circuit board, making sure that white fasteners open and catch. Use extraction/insertion tool furnished with CPU to insert (or remove) module into rack. Secure faceplate to rack using thumbscrews at top and bottom. Clear parity errors detected at initial power-up of the CPU. Refer to Chapter 2, Series Six Programming Manual (GEK-25362) for further details. I LOGIC MEMORY .-,A, FIGURE 3. DIP-SWITCH ARRAY FIGURE 4. 6000 CPU Ref. PC-S6-84-0152 PC-S&84-0153 Internal Memory Module GEK-83501 CATION Relatively small amounts of excess charge can cause very intense electrostatic fields in metal-oxide-semiconductor (MOS) devices, damaging their gate structure. When the board covers have been removed, avoid handling this circuit board in a manner which might cause electrostatic charges. Failure to observe this CAUTION could result in the destruction of the CMOS-RAM devices in this module. With the board covers in place, it is unlikely that normal handling of this module would cause any damage. I WARNING I Do not place a short circuit between the contacts at the ends of the battery. Do not attempt to recharge the battery. Failure to observe either of these WARNINGS will cause the battery to explode, possibly resulting in personal injury. Do not allow the bottom of this circuit board to come into contact with a conductive (metal) surface when the board covers are removed. Failure to observe this CAUTION could result in the discharge of the non-rechargeable lithium battery and the loss of the memory contents. ORDERING INFORMATION Circuit Board and Faceplate IC600BF504A Circuit Board Faceplate IC600CB504A IC600FP504A CATALOG NUMBER REVISION SUFFIX The equipment listed above having the catalog numbers shown and the same equipment having a higher alpha suffix is designed for listing by UL for use as auxiliary control devices. The equipment is a direct replacement for equipment having the same catalog number but a lower alpha suffix. This symbol on the nameplate means the product is listed by Underwriters Laboratories Inc. (UL Standard No. 508, Industrial Control Equipment, subsection Electronic Power Conversion Equipment.) For further information, contact your local GE Fanuc sales office. GE Fanuc Automation North America, Inc., Charlottesville, Virginia 4 JANUARY,

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PLC Distribution Factory & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PLC Distribution Factory & Supply packaging and includes a PLC Distribution Factory & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PLC Distribution Factory & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PLC Distribution Factory & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.