IC600PM508

GE Fanuc | Series Six | In Stock Ships Today GE Fanuc Series Six IC600

IC600PM508 Image

IC600PM508

  • Availability: Out of Stock
  • Units in Stock: Immediate Availablity: 6 Units!
  • Call for best Pricing+ 1 919 680 1773
  • Manufacturer: GE Fanuc
  • Description: 115-230Vac Redundant Processor Unit Auxiliary Power Supply
  • Weight: 3 lbs :: ≈ 2 kgs
  • Warranty: 1 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC600PM508 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

CPU/DPU POWER SUPPLY MODULE Source Voltage: 95 to 260 Vac Output Voltages: +5, +12,-12Vdc -.-- -.. GENERAL DESCRIPTION The CPU/DPU Power Supply module, utilized in both the Central Processor Unit (CPU) and the Data Processor Unit (DPU), is available to be used with a power source from 95 to 260 Vac. The features and benefits of this module are summarized in Table 1. The CPU/DPU Power Supply module provides regulated + 12, -12 and + 5 DC voltages to the rack backplane. The input (or source voltage), which can range in frequency from 47 Hz to 63 Hz, is applied to terminals on the front panel, then routed through a line filter, switch, and fuse to a switching power supply. The module provides electromechanical relay contacts for connection to user indicators, or any device to be activated during an alarm condition. The module also provides a voltage regulator for an optional, auxiliary battery that provides battery back-up of CMOS memory contained in the processor rack. A Keyswitch mounted on the front panel is used to select either the RUN or the STOP mode for the processor; a second Keyswitch allows the user to protect the contents of the processor memories by placing them in a READ ONLY mode. The same key operates both Keyswitches. Refer to Figure 1 (next page) for the CPU/DPU Power Supply module specifications. TABLE 1. FEATURES AND BENEFITS I FEATURES I BENEFITS I Available in one version to include both 115 chVSovped2\\\\aMhd\\\\r\\\\sarser\\\\Gax\\\\oNurp\\\\anMoRD-oa\\\\ecvrM3atM(io6\\\\cr4)iac anualand 230 Vac applications: Compatible with variety of power sources |Can be utilized in CPU and DPU racks I Reduced spare-parts inventory I Provides electromechanical-relay contacts for alarm indications Activates user-supplied power indicators Contains voltage regulator for auxiliary battery I External battery back-up of CMOS memory I 1 LOGIC OF PWR ON o O POWER PROCESSOR SUPPLY 115-2300 50.60HZ MEMORY PROTECT CPU/DPU Power Supply Module GEK-83505 Input: 95-260 Vac, 250 VA max. Frequency: 47-63 Hz Output: Total power +5 Vdc, 16.5 A max. from all outputs +12 Vdc, 1.5 A max. must be less -12 Vdc, 1.0 A max. than 90 watts. Allowable Power Interruption: 33ms minimum at 115 Vac line. Noise Immunity: Meets requirements of NEMA ICS 2-230 and ANSI C37.90A. Auxiliary Battery Input: 8-28 Vdc Dimensions: 12.46 x 9.00 x 2.75 (inches) 317 x 229 x 70 (mm) Operating Temperature: 0 to 60 C (outside of the rack) Storage Temperature: -20 C to + 80 C Humidity: 5%-95% (non-condensing) FIGURE 1. SPECIFICATIONS SIDE VIEW Internal Terminal Strip (Refer to Figure 3) Chassis Ground Terminal O 18-Pin Connector: Connects signal cable from rack backplane O Front-Panel Connector Block (Refer to Figure 4) O Power Switch/Fuse FRONT PANEL 0 CPU RUN/STOP Key Switch 0 MEMORY PROTECT Key Switch 0 POWER Light On: The voltage levels of all three DC outputs (+ 12V , -12V, + SY) ale 9a1th1n toletarive Off: At least one of these voltage levels is too low FIGURE 2. USER ITEMS Ref. PC-S6-83-0116 2 PC-S6-83-0117 CPU/DPU Power Supply Module GEK-83505 INSTALLATION These steps define the procedures to be followed when a power supply is to be replaced on a Series Six CPU or DPU rack. The tools needed are a regular screwdriver, Phillips screwdriver, and a 5/16 wrench or nut driver. 1. Stop the system by switching the top key on the CPU to STOP . 2. Switch off all units in the system, including the user s power supplies. 3. Remove all power from the system, preferably at the source (i.e. throw the main circuit breaker for the system). 4. Locate the power supply to be changed. The power supply is in the far right side of the CPU/DPU rack. 5. Remove the plastic cover on the lower portion of the power supply and, using a volt-meter, make sure there is no AC power present. 6. Take note of the location and color of the AC wires and then remove them, Also, remove Auxiliary battery and/or Alarm connection(s) . 7. At the top and bottom of the power supply, there are 1/4 turn thumbscrews. To loosen, turn the thumbscrews approximately l/4 t u r n counterclockwise. 8. Grasp the thumbscrews and gently pull outward. Be careful not to damage the internal wiring while pulling the supply out. 9. Locate the wires that extend from the back of the rack to the terminal on the power supply. These wires should be labeled or stamped with their location; the circuit boards have wire locations stamped on them also. (Refer to Table 3.) Remove these wires. There is also a plastic wire clamp holding these wires in place. Detach this from the frame if there is not a similar item on the replacement power supply, or cut the clamp if there is one on the new supply. Remove the 18-pin (PI) molex connector that is on the narrow board in the front part of the power supply. The power supply should now be completely detached from the rack. 10. Take the replacement power supply and attach the wires as shown in Figure 3. Be sure to connect the 18-pin molex connector (P1) to the power supply. Attach the wire clamp on the upper stud of the power supply frame, or if there is a clamp already there, wrap the wires in it. 11. Slide the power supply into the rack, being careful not to damage the wires. When the power supply is all the way in, turn the thumbscrews clockwise until they lock in. 12. Remove the plastic cover on the lower portion of the power supply and attach the AC wires as they were on the original supply (Refer to Step 6). Replace the plastic cover. 13. Restore system power. Turn on the CPU/DPU unit. Check to see if the POWER light is on. If it is, turn on the rest of the system and resume normal operation. 14. If the POWER Iight does not come on, the power supply is bad or there are other problems within the rack. When this occurs, you can call the Programmable Control Service Center EMERGENCY SERVICE NUMBER (804) 978-5747 for assistance. FIGURE 3. POWER SUPPLY EXTERNAL WIRING DIAGRAM Ref. PC-83-S&01 18 CPU/DPU Power Supply Module GEK-83505 If a memory auxiliary battery is used, the circuit connecting it to this module should be isolated from the rest of the system. If this CAUTION is not observed, the battery could be short-circuited. The alarm contacts consist of two sets of normally-opened and normallyc l o s e d c o n t a c t s . The terminals marked 1 NO and 1 NC are associated with Alarm Type No. 1; the terminals marked 2 NO and 2 NC with Alarm type No. 2. (Refer to I n s t a l l a t i o n a n d M a i n t e n a n c e Manual, GEK-25361 for further information on Alarm Nos. 1 and 2.) AUXILIARY BATTERY ALARM RELAY CONTACTS \\\\\\\\SO\\\\_ ATED ) IN0 INC i COM I 2N0 2NC The user devices connected to each set of Alarm terminals on this module should present a resistive load drawing no more than one amp of current at no greater than 115 Vac/28 Vdc. Failure to observe this CAUTION may result in damage to the circuit board. NOTE During normal operation the alarm relays are energized. During an alarm condition the contacts marked 1NO and 2N0, o p e n , and those marked 1NC and 2NC, close. LINE 1 IL1 1 LINE 2 (L2) GROUND (G) AC INPUT LlNE FIGURE 4. FRONT-PANEL TERMINAL BLOCK ORDERING INFORMATION Module 95 to 260 Vac Power Supply Module IC600PM500B CATALOG NUMBER REVISION SUFFIX The equipment listed above having the catalog numbers shown and the same equipment having a higher alpha suffix is designed for listing by UL for use as auxiliary control devices. The equipment is a direct replacement for equipment having the same catalog number but a lower alpha suffix. The UL symbol on the nameplate means the product is listed by Underwriters Laboratories Inc. (UL Standard No. 508, Industrial Control Equipment, subsection Electronic Power Conversion Equipment.) For further information, contact your local GE Fanuc sales office. GE Fanuc Automation North America, Inc., Charlottesviile, Virginia JANUARY, 1984 Ref. PC-S&83-0119