IC600PM543

GE Fanuc | Series Six | In Stock Ships Today GE Fanuc Series Six IC600

IC600PM543 Image

IC600PM543

Same Day - Free Shipping

  • Manufacturer: GE Fanuc
  • Description: 24Vdc Redundant Processor Unit Main Power Supply
  • Weight: 3 lbs :: ≈ 2 kgs
  • Warranty: 2 Years
  • Product Revisions Available:
  • Other Available Revisions of the IC600PM543 : A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z,

Product Manual Excerpt

Redundant Processor Unit Main Power Supply Module General Description The Redundant Processor Unit (RPU) is designed to operate either with a single (Main) power supply module or with two power supply modules, the second being the Auxiliary Power Supply. The AC Main Power Supply module accepts 115 Vac or 230 Vac and provides regulated +5V and +12 Vdc to the RPU backplane. AC power is connected to terminals on the front panel and routed through a line filter, switch and fuse to a switching power supply. The DC Main Power Supply module accepts 24 Vdc and provides regulated +5V and +12 Vdc to the RPU backplane. DC power is also connected to terminals on the front panel and routed through a line filter, switch and fuse to a switching power supply. Terminals on the front panel enable the user to access electromechanical relay contacts for connection to user indicators, or any device to be activated during an alarm condition. A Light-Emitting Diode (LED), visible through a lens on the front panel, is an indicator of the status of the module. A keyswitch mounted on the front panel is used to select either the RUN or HOLD mode of the RPU. A second keyswitch allows the user to select Central Processor Unit (CPUl), CPU2 or AUTO. A full description of the alarm relay fault conditions as well as the RUN/HOLD switch and CPUl/AUTO/CPU2 switch operation is given in the RPU Manual, GEK-25366. Other features and benefits are listed in Table 1, while Table 2 shows module specifications. Table 1. Features and Benefits FEATURES Input Voltage Requirements: 95 - 260 Vac 47-63Hz or 24 Vdc BENEFITS Compatible with a variety of power sources Can be utilized along with an Auxiliary Power Supply module Power Supply system redundancy Provides access to electromechanical relay contacts Visible LED monitor Activates user-supplied fault annunciators Displays status of output voltages of module Table 2. AC - DC Specification Input: AC: 95 - 260 Vac, 250 Va maximum Output: Allowable Power Interruption: Noise Immunity: Dimensions: Operating Temperature: Storage Temperature: Humidity: Frequency: 47-63 Hz DC: 25Vdc, V maximum Frequency: 47-63 Hz +5 Vdc at 15.5 Amps maximum +I2 Vdc at 1.0 Amp maximum 33 ms minimum @ 115 Vac line Meets requirements of NEMA ICS 2-230 and ANSI C37.90A 12.46 x 9.00 x 2.75 (inches) 317 x 119 x 70 (mm) 0 to 60 C (outside of rack) -40 C to 70 C 5% to 95 % (non-condensing) 0 2 Redundant Processor Unit GEK-84861B O iD STUD B 56840132 7/1///rillir tirfesn Eni\' 4 1 SEE FIGURE 2 r 411 9 PSTB 0 BACKPLANE BUS AND SIGNAL CABLE 1:D Figure 1. User Items 1. Front Panel Connector Block 6. P1, 16-Pin Connector 2. Power Switch 7. P6, 3-Pin Connector 3. RUN/HOLD Keyswitch 8. 2A Fuse 4. CPU1/CPU2/AUTO Keyswitch 9. Power Supply Terminal Board 5. Power-On LED 10. Cable Clamp On: The voltage levels of both DC outputs 11. Chassis Ground Terminal (+12V and +5V) are within tolerance. Off: At least one of these voltage levels is out of tolerance. Redundant Processor Unit 3 GEK-84861B Installation 3. Disconnect wiring to AC and alarm terminals. The RPU is designed to operate either with a single power supply module, or with two power supply modules. The removal and replacement guidelines of a power supply module in a dual supply system also apply to a single supply system. When two power supply modules are used, the system offers power supply redundancy in such a way that: - I f both supply modules are functioning normally, one module has the load and the other is on standby. - I f one power supply module fails, the other either continues to carry the load or automatically assumes it without affecting the normal operation of the RPU system. - A power supply module should be able to be removed or installed while the RPU system is up and running without interrupting the normal operation of the RPU system. - However, because there may be live voltages on a power supply module, even after the switch to that module is turned off, the following removal and replacement guidelines should be observed. Power SuppIy Module Replacement (RPU running) 1. Switch RUN/HOLD switch to HOLD. 2. Remove power to failed power supply by disconnecting AC source. S6840133 BACKPLANE BUS CABLE WIRING WIRING (STAMPED) PSTB-9 (BLACK) PSTB- 7 (WHITE) PSTB-4 (BLACK) STUD B (GREEN) CONNECTS TO +5v COM +12v GND STUD B +5V COM COM 4 3 2 GND AC AC (+12V) I (+12V) l-1 2Vl Figure 2. Power Supply Terminal Block Figure 3. Front Panel Terminal Block 4. Remove partition faceplate between power supplies. 5. Release quarter-turn fasteners and slide power supply out to expose connectors located behind faceplate. 6. Disconnect the 4 wires from the supply chassis and 2 connectors from the monitor circuit board. 7. Remove the failed power supply. 8. Reverse the above procedure to install the replacement module. 9. After the replacement power module has been installed apply power to module and verify that the POWER-ON LED is on. 10. Switch RUN/HOLD switch to RUN. Care should be taken to avoid shorting components or leads on the module being replaced. The free-hanging connectors from this module should also be handled or positioned in such a way that they are not brought into contact with conductive surfaces. NO CONNECTION ALARM RELAY CONTACTS (ISOLATED) IN0 INC COM 2NO 2NC 8al0188 aI 0 95840134 NO CONNECTION LINE 1 (Ll ) LINE 2 (12) GROUND (G) 4 Redundant Processor Unit GEK-84861B ) CAUTION ) NOTE The alarm contacts consist of two sets of Form C contacts. The terminals marked 1 NO and 1 NC are associated with Alarm Type No. 1; the terminals marked 2 NO and 2 NC with Alarm Type No. 2. Incorrectly wiring these alarms may cause damage to your equipment (see the RPU Manual, GEK-25366, for further information on Alarm Nos. 1 and 2.) The user devices connected to each set of alarm terminals on this module should present a resistive load drawing no more than one ampere (1A) of current at no greater than 115 Vac/28 Vdc. Failing to observe this caution may result in damage to the module. During normal operation, the alarm relays are energized. During an alarm condition, when the relay becomes de-energized, the contacts marked 1 NO and 2 NO open, and those marked 1 NC and 2NC close. NOTE The two keystrokes (Run/Hold, Pwr/Auto/ CPU2) depend on the Main Power Supply for their circuits. If the Main Power Supply fails, the RPU firmware will behave as though the Run/Hold keyswitch has been switched to Hold, even if an Auxiliary Power Supply is present. Table 3. Ordering Information 95-260Vac Main Power Supply 24 Vdc Main Power Supply IC600PM507 IC600PM543 The UL symbol on the nameplate means the product is listed by Underwriters Laboratories Inc. (UL Standard No. 508, Industrial Control Equipment, subsection Electronic Power Conversion Equipment.) For further information, contact your local GE Fanuc sales representative. GE Fanuc Automation North America, Inc., Charlottesville, Virginia

Need To Order A Specific Revision?

Give us a call at 1-800-360-6802 or 1-919-535-3180. We can help you with your Revision specific needs.


UPS Ground shipping is always FREE!


What is New Surplus?

These “New Surplus” units are a great cost saving alternative. This product is in the original manufacturer’s packaging with all sub-assemblies and documentation. Comes with a PLC Distribution Factory & Supply 3-year warranty.


UPS Ground shipping is always FREE!


What is Surplus New?

Surplus New - New unused and includes all sub-assemblies and documentation. Product may ship in manufacturer or PLC Distribution Factory & Supply packaging and includes a PLC Distribution Factory & Supply 3 Year Warranty.


UPS Ground shipping is always FREE!


What is Reconditioned?

Reconditioned products from PLC Distribution Factory & Supply are a cost-effective alternative to new and obsoleted PLC products. Every part is reconditioned down to the circuit board level. All parts are thoroughly inspected and hand-cleaned before being functionally tested in a fully configured system.


Our Reconditioned Products always come with a PLC Distribution Factory & Supply 2-Year Warranty.

UPS Ground shipping is always FREE!


110% PRICE MATCH GUARANTEE


We stand behind our prices with a 110% price match guarantee. If you buy a part from us and, within seven days of purchase, find that part advertised on an authorized distributor's website for less, simply contact us and give us a link to the lower advertised price and we'll refund you 110% of the difference between your purchase price and the advertised lower price. The part must be in-stock for immediate shipment and be in similar condition. All pricing must be displayed without signing in.

Repair Service


3-5 Days for most repairs. 24 hour repair upon request at no extra charge. If part is unrepairable, we will exchange with a working unit or return unrepaired.